C0005

SIGNAL CFG — Signal configuration (predefined basic configurations)

8.4 Code table

PDF s. 243 ↗
C0006

OP MODE — Motor control operation Depending on C0086

8.4 Code table

PDF s. 243 ↗
C0009

LECOM ADDRESS — LECOM device address

8.4 Code table

PDF s. 243 ↗
C0012

TIR (ACC) — NSET: Acceleration time T ir for the main setpoint of NSET (related to the speed variation 0 ... n max )

8.4 Code table

PDF s. 244 ↗
C0013

TIF (DEC) — NSET: Deceleration time T if for the main setpoint of NSET (related to the speed variation n max ... 0)

8.4 Code table

PDF s. 244 ↗
C0021

SLIPCOMP — Slip compensation Only active with sensorless control below

8.4 Code table

PDF s. 244 ↗
C0022

IMAX CURRENT — I max limit current Depending on C0086

8.4 Code table

PDF s. 244 ↗
C0026

FCODE (OFFSET) — FCODE (AIN offset)

8.4 Code table

PDF s. 245 ↗
C0027

FCODE (GAIN) FCODE (GAIN) — FCODE (AIN gain)

8.4 Code table

PDF s. 245 ↗
C0032

FCODE GEARBOX — FCODE (gearbox factor numerator)

8.4 Code table

PDF s. 245 ↗
C0033

GEARBOX DENOM — Gearbox factor denominator

8.4 Code table

PDF s. 245 ↗
C0037

SET−VALUE RPM — Setpoint selection (rpm)

8.4 Code table

PDF s. 245 ↗
C0039

JOG SET−VALUE JOG SET−VALUE — NSET JOG setpoints

8.4 Code table

PDF s. 245 ↗
C0040

CTRL ENABLE — RFR controller enable

8.4 Code table

PDF s. 245 ↗
C0049

NSET−NADD — NSET: Additional setpoint

8.4 Code table

PDF s. 245 ↗
C0050

MCTRL−NSET2 — MCTRL: n set at speed controller input

8.4 Code table

PDF s. 245 ↗
C0056

MCTRL−MSET2 — MCTRL−MSET2 (Mset)

8.4 Code table

PDF s. 246 ↗
C0058

ROTOR DIFF — Rotor displacement angle of motor (offset

8.4 Code table

PDF s. 246 ↗
C0059

MOT POLE NO. — Number of motor pole pairs

8.4 Code table

PDF s. 246 ↗
C0060

ROTOR POS — Motor rotor position 1 revolution = 2048 inc

8.4 Code table

PDF s. 246 ↗
C0061

HEATSINK TEMP — Heatsink temperature

8.4 Code table

PDF s. 246 ↗
C0064

UTILIZATION — Device utilisation I × t of the last 180 s C0064 >100 % releases trip OC5

8.4 Code table

PDF s. 246 ↗
C0066

MOTOR LOAD — × t utilisation of the motor

8.4 Code table

PDF s. 246 ↗
C0070

VP SPEED CTRL — V pn speed controller Depending on C0086

8.4 Code table

PDF s. 246 ↗
C0071

TN SPEED CTRL — T nn speed controller

8.4 Code table

PDF s. 246 ↗
C0072

TD SPEED CTRL — T dn speed controller

8.4 Code table

PDF s. 246 ↗
C0075

VP CURR CTRL — V pi current controller Depending on C0086

8.4 Code table

PDF s. 246 ↗
C0076

TN CURR CTRL — T ni current controller

8.4 Code table

PDF s. 246 ↗
C0077

VP FIELD CTRL — V pF field controller

8.4 Code table

PDF s. 246 ↗
C0078

TN FIELD CTRL — T nF field controller

8.4 Code table

PDF s. 246 ↗
C0081

MOT POWER — Rated motor power acc. to nameplate Depending on C0086

8.4 Code table

PDF s. 247 ↗
C0084

MOT RS — Motor stator resistance Depending on C0086

8.4 Code table

PDF s. 247 ↗
C0085

MOT LS — Motor leakage inductance Depending on C0086

8.4 Code table

PDF s. 247 ↗
C0086

MOT TYPE — Motor type selection Depending on the controller used

8.4 Code table

PDF s. 247 ↗
C0087

MOT SPEED — Rated motor speed Depending on C0086

8.4 Code table

PDF s. 247 ↗
C0088

MOT CURRENT — Rated motor current Depending on C0086

8.4 Code table

PDF s. 247 ↗
C0089

MOT FREQUENCY — Rated motor frequency

8.4 Code table

PDF s. 247 ↗
C0090

MOT VOLTAGE — Rated motor voltage Depending on C0086

8.4 Code table

PDF s. 247 ↗
C0091

MOT COS PHI — Motor cos Depending on C0086

8.4 Code table

PDF s. 247 ↗
C0093

DRIVE IDENT — Controller identification

8.4 Code table

PDF s. 247 ↗
C0094

PASSWORD — Password Parameter access protection for the

8.4 Code table

PDF s. 248 ↗
C0095

ROTOR POS ADJ — Rotor position adjustment of a synchronous

8.4 Code table

PDF s. 248 ↗
C0096

AIF PROTECT. CAN PROTECT. — Extended password protection for bus

8.4 Code table

PDF s. 248 ↗
C0101

NSET−TIR (ACCELERATIO — NSET: Additional acceleration for the main setpoint

8.4 Code table

PDF s. 248 ↗
C0103

NSET−TIF NSET−TIF — NSET: Additional deceleration times for the main

8.4 Code table

PDF s. 248 ↗
C0108

FCODE (GAIN AOUT) — FCODE (AOUT gain)

8.4 Code table

PDF s. 248 ↗
C0109

FCODE (OFFSET AOUT) — FCODE (offset AOUT)

8.4 Code table

PDF s. 248 ↗
C0114

DIGIN1 POL DIGIN2 POL — DIGINterminal polarity

8.4 Code table

PDF s. 248 ↗
C0116

FDO−00 ... — Signal configuration of the free digital

8.4 Code table

PDF s. 249 ↗
C0117

DIGOUT1 DIGOUT2 — Signal configuration DIGOUT Depending on C0005

8.4 Code table

PDF s. 249 ↗
C0118

DIGOUT1 POL DIGOUT2 POL — Terminal polarity DIGOUT

8.4 Code table

PDF s. 249 ↗
C0120

OC6 LIMIT — Threshold for the × t monitoring (motor). 0 = I2 × t monitoring switched off

8.4 Code table

PDF s. 249 ↗
C0127

OC8 LIMIT — Threshold for the × t advance warning (motor).

8.4 Code table

PDF s. 249 ↗
C0128

TAU MOTOR — Thermal time constant of the motor

8.4 Code table

PDF s. 249 ↗
C0130

ACT TI — NSET: Active T i times of NSET

8.4 Code table

PDF s. 249 ↗
C0134

RFG CHARAC — NSET: Ramp function generator characteristic for main setpoint

8.4 Code table

PDF s. 249 ↗
C0142

START OPTIONS — Start option Automatic start inhibited after

8.4 Code table

PDF s. 250 ↗
C0150

STATUS WORD — Status word when linked to automation

8.4 Code table

PDF s. 250 ↗
C0151

FDO (DW) — Hexadecimal display of the free digital

8.4 Code table

PDF s. 250 ↗
C0156

STAT.B0 STAT.B2 — Configuration of the free bits of the status

8.4 Code table

PDF s. 250 ↗
C0157

(C0156/1) ... — Display of the freely definable bits of the status word

8.4 Code table

PDF s. 250 ↗
C0168

FAIL NO. ACT FAIL NO. OLD1 — List of faults occurred

8.4 Code table

PDF s. 250 ↗
C0169

FAILTIME ACT FAILTIME OLD1 — List of the times when the faults occurred

8.4 Code table

PDF s. 251 ↗
C0170

COUNTER ACT COUNTER — List of how often the faults have occurred

8.4 Code table

PDF s. 251 ↗
C0173

UG LIMIT — DC−bus voltage thresholds

8.4 Code table

PDF s. 251 ↗
C0178

OP TIMER — Elapsed−time meter Time when the controller was enabled

8.4 Code table

PDF s. 251 ↗

Açıklamalar kılavuzdaki özgün dildedir. Parametreyi değiştirmeden önce ilgili PDF sayfasındaki kapsam, birim, aralık ve erişim koşullarını kontrol et.